The curb should provide a minimum clearance of 10 inches between the top of the fi nished roof surface and the top of the wood nailer continuous around the curb.
Seismic roof curb requirements.
Additional roof curb anchoring and methods of securing equipment to the curb are also a requirement and must be adhered to for the certification to be valid.
The york curb uses only un treated wood.
Roof curbs insulated roof curbs.
As the sizes increase beyond 12 000 lb and 40 ft of length attachment to a sheet metal roof curb becomes impractical.
Base shall be constructed complete with all welded corners and wood nailers.
Any roof curb rigid or vibration that have been engineered and stamped to meet current ibc 2015 you may also hear this as complying or calculated.
Curbs solidly braced or bolted directly to the building structure without vibration isolation.
For installation on flat membrane built up roofs requiring seismic rating.
It is suitable for units in the 5 000 lb to 12 000 lb 40 ft long class for most seismic and wind conditions.
The goal is to match or exceed the seismic roof curb design value referred to as the ss value.
The additional requirements are detailed on each stamped submittal drawing.
Flange screwed to 15 32 osb roof deck 8 2 7 24 x 24 curb with exhaust fan fan screwed to curb 2 5 8 36 x 36 curb with exhaust fan fan screwed to curb 3 3 9 5 9 x 3 8 curb with 2 8 high hvac unit hvac unit screwed to curb 4 5 10 5 9 x 3 8 curb with 2 8 high relief air hood hood screwed to curb 35 6.
Meets seismic code requirements.
Ss is the mapped maximum credible earthquake five percent dampened spectral response acceleration parameter at short periods as defined in asce 7 10 section 11 4 1.
Additionally seismic requirements are not fulfilled by just ordering a seismically stamped roof curb.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Non insulated roof curbs.
Icc es ac 156.
For these applications esr s andmegacurb s are required.
Curb adapters retro mate.
Catwalk service platforms.
Furnish and install prefabricated seismic roof curbs as required to meet seismic requirements.
16 gauge galvanized steel.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
All welds coated after fabrication.
Equipment mounting supports.